Sp_Bd_bi4.md 1.66 KB

Sp_Bd_bi4 (procedure)

@author:zhucx @date:20220111 @describe: 三屏设备

  • Type: PROCEDURE
  • Deterministic: NO
  • SQL data access: CONTAINS SQL

Parameters

# Mode Name Type
1 IN iFlag int
2 IN iTmpCheck int
3 IN sFormGuid varchar(100)
4 IN sGuid varchar(100)
5 IN sLoginId varchar(100)
6 OUT sReturn varchar(4000)
7 IN sBrId varchar(100)
8 IN sSuId varchar(100)
9 OUT sCode int

Body

Body is not pre-cached. To inspect: mysql --defaults-file=~/.my.cnf -e 'SHOW CREATE PROCEDURESpBd_bi4'._

Narrative

Business context: 三屏设备 — three-screen device 现场看板 for a specific 3-PLC cluster on the workshop floor. Sibling of the bi20–bi24 four-tile family but only 3 tiles wide.

What it does: Hardcodes a 3-row p_Bd_PlcNo_No(iPlcNo,iNo) map for PLCs 10, 11, 12, then for each PLC reads elemachine/plc_currentmachinevalue/mft_workorder* to assemble per-machine 当前状态/当前工单/已生产数量/调机时间 tiles into p_Bd_workshop5, emitting a JSON board into sReturn.

Invocation: No form-master sSqlStr, no gdsmodule hook, no other-routine caller, no install script under xly-src/script/, no Java caller. Status: appears orphan — likely a one-off dashboard variant that may still be reachable via an external HTTP endpoint by proc-name. Candidate for maintainer audit.

Flag: header date 20220111 matches the bi16-24 cohort but the bi4 numbering is out of band (the rest run bi16–24). PLC list 10, 11, 12 tenant-deployment-specific.